Calculate the optimal inverter size based on your PV array configuration. Includes temperature-corrected voltage calculations and DC/AC ratio optimization.
Generic starting values, not a datasheet — a preset supplies Voc, Vmp, Isc, Imp and βVoc only; βVmp and NOCT still come from your module datasheet.
MODULE TEMPERATURE PARAMETERS
Negative value, as printed on the datasheet. Filled from the CEC library or a generic preset on selection.
Negative value. Not in the CEC library — γPmax is a different quantity, so take βVmp from your module datasheet.
Nominal operating cell temperature. Filled from the CEC library on selection.
These three come off the module datasheet and set the temperature-corrected string voltages. Leave one blank and the calculation is refused by name rather than completed from an assumed value.
Record-low site temperature — sets cold Voc. Not pre-filled.
Maximum site temperature — sets hot Vmp. Not pre-filled.
minTemp is required — the record-low site temperature sets the cold Voc that the inverter must withstand. It is not replaced with a default.
— AWAITING INPUT —
Enter your panel specifications and string configuration to get inverter recommendations.
Optimal - balanced performance and cost
Conservative - minimal clipping, higher upfront cost
Aggressive - lower cost, some clipping on peak days